Indian Construction Industry

Ace Instruments

Lab & Scientific Products

Contact
For Trade

Lab & Scientific Products By Ace Instruments

Dry Block Temperature Calibrator (Range: 50 to 650?C) with Thermocouples (T, J, K, N, R, S) for Calibration Labs, Pharmaceutical Divisions, Thermal Plants, Metallurgical Plants Model: AI-DBC-02 - Product Features
  • Range: Ambient to 650 C | Accuracy: ?0.6 C | Bath Stability: ?0.05 C | Stabilization Time: 20 Min. | Heating Time: 30 to 32 Min. (Ambient to 650 C) | Resolution: 0.1 C | Units: C / F Switchable | Display: Graphical with LED Backlight | Power Supply: 230V AC 5% / 50Hz,1.2 KW for 650DBC
  • Transmitter Supply: 24V DC 10% (Loop Powered) |Block Diameter: 25.4 mm | Block Depth: 120 mm | Insertion Tube Depth: 110 mm | Temperature Setting: Digital Display through feather touch keypad | Display Stability: ?0.2 C | Radial uniformity Fixed Steps for: ?0.3 C with similar probes | Switch Test: Continuity check with OPEN / CLOSE indication |
  • Measuring Parameters: mA, mV, Volts, Ohms, RTD3 (Pt 100)3 | mA Range: 0 to 25 mA; Resolution: 0.001 mA; Accuracy: ?0.025% of Reading + 10 ?A | mV Range: 0 to 1000.0 mV; Resolution: 0.01 mV; Accuracy: ?0.025% of Reading + 0.25 mV | Volts Range: 0 to 10.000 V; Resolution: 0.001 V; Accuracy: ?0.025% of Reading + 3 mV | Ohms Range: 0 to 400 Ohms; Resolution: 0.01 Ohms; Accuracy: ?0.025% of Reading + 0.1 Ohm | RTD3 Range: -200 to 8500 C; Resolution: 0.10 C; Accuracy: ?0.025% of Reading + 0.30 C |
  • Thermocouple Types: T, J, K, N, R, S | Thermocouple Range( T,J,K,R,S): -200 to 400 C; Resolution: 0.1 C; Accuracy: ?0.025 % of Reading + 1 C |Thermocouple Range(R,S): 300 to 1760 C; Resolution: 1 C; Accuracy: ?0.025 % of Reading + 1 C |
  • Supply Scope: 1 Unit of DBC-02 Dry Block Calibrator, Power Cable, 1 Unit of Test Lead (2 Wire), Insertion Tube: Dual Hole - 1 x 1/4" + 1 x 12.5 mm, Dual Hole - 1 x 1/4" + 1 x 8.2 mm, 1 Unit of Insertion Tool, 2no.s of 6A Spare Fuses, Instruction Manual and Factory Calibration Certificate | Applications: Calibration Labs, Pharmaceutical Divisions, Thermal Plants, Metallurgical Plants Temp dry well block temperature probe calibrator rtd k type thermocouple stimulator calibration equipment.
 
8 Channel Datalogger with Standard Software for Pharmaceutical Industries, Freezers, Digital data logger , temperature recorder, Cold Chains, Autoclaves, Chemical Industry Alongwith Factory Calibration Certificate Model: AI-800S - Product Features
  • The instrument can at a time measure 8 inputs on its 8 channels. These inputs can be all 8 of one type (say all 8 of vacuum or Pressure or Temperature etc.) Or of different types; 2) Alternatively, the instrument can be used to read & record any 1 Input, on any 1 Channel & the remaining channels can be disabled using the Front keys.
  • Scanner: The instrument can be used as a plane scanner where in the only purpose of the instrument is to display the input value from the sensors. Scanner with Memory (Data Logger): The instrument can be Provided with 5000 Readings Memory Built In for each of the 8 Channels & provided with any standard communication port (RS 232 or RS485) for Computer connectivity
  • Scanner With Printer Port: The instrument can be provided with a Parallel printer port for printing directly onto a 80/132 Channel Printer Without using a computer. The print interval (time gap between Successive Printouts) can be programmed using the front keys; Input Type: 8 Nos. of Vacuum / Pressure / Humidity (4-20 mA), Temperature (4-20 mA) RTD Pt-100 Sensors, 0 -1/ 0-5 / 0-10 V DC, Any Standard Thermocouple (To be specified at time of ordering); Accuracy: ?0.25% of Full Scale.
  • Display: 1 Digit for Channel No; 4 Digits for Process Variable; Memory: 5000 Records of Each of the 8 Channels; Modes: Channel Skip, Hold & Auto Modes. Scan Time: 1 to 59 seconds (User Programmable); Relay/ Alarm: 2 Relay Contacts for Alarm & Trip; Power Supply: 230V AC, 50Hz, Single Phase.
  • Software: ACE SOFT 21 CFR Part 11 Compliant Software With Audit Trail Reporting, Online Tabular View & Data Graphing| Supply Scope: 1 Unit of 8 Channel Datalogger, Instruction Manual and Factory Calibration Certificate | Applications: Applications: Pharmaceutical Industries, Freezers, Cold Chains, Autoclaves, Chemical Industries. Multichannel temperature humidity universal recorder cryogenic data logger laboratories
 
Dry Block Temperature Calibrator (Range: 50?C to 350?C) with Thermocouples (T, J, K, N, R, S) for Calibration Labs, Pharmaceutical Divisions, Thermal Plants, Metallurgical Plants Model: AI-DBC-01 - Product Features
  • Range: Ambient to 350 C | Accuracy: ?0.4 C | Bath Stability: ?0.05 C | Stabilisation Time: 15 Min. | Heating Time: 18 to 20 Min. (Ambient to 350 C) | Cooling Time: 30 to 35 Min (350 to 100 C) | Resolution: 0.1 C | Units: C / F Switchable | Display: Graphical with LED Backlight | Power Supply: 230V AC 5% / 50Hz,1.2 KW for 500 W for 350 DBC |
  • Transmitter Supply: 24V DC 10% (Loop Powered) |Block Diameter: 25.4 mm | Block Depth: 120 mm | Insertion Tube Depth: 110 mm | Temperature Setting: Digital Display through feather touch keypad | Display Stability: ?0.2 C | Radial uniformity Fixed Steps for: ?0.3 C with similar probes | Switch Test: Continuity check with OPEN / CLOSE indication |
  • Measuring Parameters: mA, mV, Volts, Ohms, RTD3 (Pt 100)3 | mA Range: 0 to 25 mA; Resolution: 0.001 mA; Accuracy: ?0.025% of Reading + 10 ?A | mV Range: 0 to 1000.0 mV; Resolution: 0.01 mV; Accuracy: ?0.025% of Reading + 0.25 mV | Volts Range: 0 to 10.000 V; Resolution: 0.001 V; Accuracy: ?0.025% of Reading + 3 mV | Ohms Range: 0 to 400 Ohms; Resolution: 0.01 Ohms; Accuracy: ?0.025% of Reading + 0.1 Ohm | RTD3 Range: -200 to 8500 C; Resolution: 0.10 C; Accuracy: ?0.025% of Reading + 0.30 C |
  • Thermocouple Types: T, J, K, N, R, S | Thermocouple Range(T,J,K,N): -200 to 400 C; Resolution: 0.1 C; Accuracy: ?0.025 % of Reading + 1 C | Thermocouple Range(R, S): 300 to 1760 C; Resolution: 1 C; Accuracy: ?0.025 % of Reading + 1 C |
  • Supply Scope: 1 Unit of DBC-01 Dry Block Calibrator, Power Cable, 1 Unit of Test Lead (2 Wire), Insertion Tube: Dual Hole - 1 x 1/4" + 1 x 12.5 mm, Dual Hole - 1 x 1/4" + 1 x 8.2 mm, 1 Unit of Insertion Tool, 2no.s of 6A Spare Fuses, Instruction Manual and Factory Calibration Certificate | Applications: Calibration Labs, Pharmaceutical Divisions, Thermal Plants, Metallurgical Plants.
 
Testo 545 Light Intensity Measuring Instrument With Data Storage - Product Features
  • Light Range: 0 to 100000 Lux, Accuracy: Accuracy to DIN 13032-1: F1 = 6 % V (Lambda) adaptation, F2 = 5 % cos like rating, Class C according to DIN 5032-7, Resolution: 1 Lux for (0 to 32000 Lux), 10 Lux for (0 to 100000 Lux)
  • Operating Temperature: 0 C to +50 C; Storage Temperature: -20 C to +70 C; Display type: LCD; Display size: 2 lines
  • Data transfer: RS232 cable connects instrument to PC (1.8 m) for data transfer; Memory: 3,000 measuring values
  • Housing: ABS; Battery type: 9V block battery; Battery life: 50 h; Connection: Fixed cable, coiled
  • Accessories: Testo 545 light meter with permanently attached sensor, calibration certificate, batteries.
 
Industrial Process Calibrator used for Calibration of process control instruments, Temperature & pressure transmitters, I/P convertors, Field-level transmitters, Flow transmitters Model: BTH C9 - Product Features
  • Measuring Parameters: Frequency, OHM, Analog Transducer, DC mA, RTD, Thermocouples, Resistance, RTD Measurement, TC Measurrement, Frequency Count, Diode Test & Continuity Test.
  • Process Meter Measurements: Range: DC Voltage Measurement: Range: 4.000V, Resolution: 0.001V, Accuracy: 0.2% + 4; Range: 40.00V, Resolution: 0.01V, Accuracy: 0.2% + 4; Range: 400.0V, Resolution: 0.1V, Accuracy: 0.2% + 4; DC mV Measurement: Range: 40.00mV, Resolution: 0.01mV, Accuracy: 0.5% + 6; Range: 400.0mV, Resolution: 0.1mV, Accuracy: 0.2% + 4
  • AC Voltage Measurement: Range: 400.0mV, Resolution: 0.1mV, Accuracy: 1.0% + 4; Range: 4.000V, Resolution: 0.001V, Accuracy: 0.5% + 4; Range: 40.00V, Resolution: 0.01V, Accuracy: 0.5% + 4; Range: 400.0V, Resolution: 0.1V, Accuracy: 0.5% + 4; DC Current Measurement: Range: 40.00mA, Resolution: 0.01mA, Accuracy: 0.2% + 4; Range: 400.0mA, Resolution: 0.1mA, Accuracy: 0.2% + 4
  • AC Current Measurement: Range: 40.00mA, Resolution: 0.01mA, Accuracy: 0.5% + 4; Range: 400.0mA, Resolution: 0.1mA, Accuracy: 0.5% + 4; Operating Temperature: 5 C to 50 C; Operating Relative Humidity: <80% RH, Storage Temperature: -10 C to 55 C, Storage Humidity: < 90% RH
  • Power Supply: 6V batteries (4*1.5V alkaline AAA batteries or 4*1.5V Ni-MH AAA batteries); Maximum Voltage: 600Vp-p (Maximum Voltage between all input jacks & earth ground), 30V DC (Maximum Voltage between all output jacks & earth ground); Accessories: A copy of user manual, a set of industrial test lead (with alligator) clips and two 63mA/250V fast-blow fuses; Safety: Compiled with IEC61010 (Safety standard issued by International Electro-technical commission.
 
Testo 270 Oil Analysis Kit Oil Thermometer for Temperature and Total Polar Material Measurement in Deep Fryers Digital Thermometer for Cooking Oil in Fryers - Product Features
  • TEMPERATURE AND TPM; The testo 270 temperature gun checks temperature and Total Polar Material, thus ensuring that only high quality, nutritionally adequate foods, are served to customers
  • QUICK AND COST-EFFECITVE; The temperature gauge works fast and reliably while enabling significant cost saving by decreasing the probability of changing the expensive resource oil too soon
  • CONVENIENT; The kitchen appliance for deep fryer with oil filtration is designed in a way that protects the hand from hot oil. It is cleanable under running water (IP65) and has an intuitive traffic-light system for TPM levels
  • QUALITY ASSURANCE; Determining the TPM in a deep fryer with basket is a key method to ensure high quality frying oil and hence fried food with a harmless nutritional value. It should never exceed 24%
  • USER-FRIENDLY; Its ergonomic, rugged design, backlit display, color-coded alarms, and hold- and auto-hold function make the temperature probe a practical, intuitive everyday tool
 
High Accuracy Oxygen Gas Detector (Range: 0-25 Vol%) Drager Personal Safety for Zone 0 with IP68 Protection for Chemical Industries by Drager Model: PAC-6500 - Product Features
  • Part Number: 83 26 332 | Features: Easy fastening with tightly closing crocodile clip | Illuminating D-Light shows device is tested and ready | Robust housing with handy design for tough conditions | Clear colour coding prevents mistakes
  • Easily replaceable Filter membrane protects the sensor | Large display shows all important information | 360 alarm signal can be easily seen from all sides
  • Drager Pac 6500 O2: Measuring Range: 0 - 25 Vol.% | Alarm thresholds A1/A2: 19 / 23 Vol.% | Operating Temperature: -30 C to +55 C | Operating Humidity: 10 to 90% RH (non condensing) | Operating Pressure: 700 - 1,300 hPa
  • Battery Life: 2 Years | Approval: cCSAus, IECEx, ATEX, CE | Dimensions: 64 X 84 X 20 mm | Weight: 106 Grams |
  • Supply Scope: 1 unit of Drager Pac 6500-O2 monitor, 1 unit of Calibration Cap, Instuction Manual, Software CD | Applications: Chemical Industry, Oil & Gas industry, Mining, Federal Government, Ignition Interlock Services
 
Ace AI-DPI-2200 Hand Operated Vacuum and Pressure Pump Range: -1 to 3 bar (Vacuum Gauge Alongwith Pump) - Product Features
  • Model: AI-DP1-2200; Measuring Parameters: Pressure and Vacuum | Vacuum Range: Ambient to -0.9 Kg/Cm?; Pressure Range: Ambient to 30 Kg/Cm (30 Bar)
  • Model: AI-DP1-2200; Measuring Parameters: Pressure and Vacuum | Vacuum Range: Ambient to -0.9 Kg/Cm?; Pressure Range: Ambient to 30 Kg/Cm (30 Bar)
  • Material Of Construction: Aluminium and Stainless Steel; Weight Approx. 1.5 Kgs.
  • Supply Scope: Vacuum gauge with Hand pump and Instruction manual
  • Applications: Calibration Labs, Field Calibration, Pressure Gauge Calibration, Pressure Transmitter Calibration.hand pump portable vaccum guage hand operated pneumatic low pneumatic pressure comparator calibrator 30 bar
 
 
If you have a business establishment in india,

Contact us

to list your business related to any construction categories.
 
Construction Events
To Know more about the events about Air Conditioners, Basements, Bathrooms, Bedrooms, Cabinets, Decorating, Design Plans, Doors, Electrical Lightings, Flooring, Home Security, Kitchen, Landscape, Painting, Plumbing, Fixtures and many more..
 
 
Facebook Twitter Instagram LinkedIn
© 2007 - IndianConstructionIndustry.com. All Rights Reserved
Home  |  Overview  |  Advertise  |  Link to us  |  About us  |  Contact us  |  Sitemap  |  Privacy Statement