Dry Block Temperature Calibrator (Range: 50 to 650?C) with Thermocouples (T, J, K, N, R, S) for Calibration Labs, Pharmaceutical Divisions, Thermal Plants, Metallurgical Plants Model: AI-DBC-02 - Product Features
- Range: Ambient to 650 C | Accuracy: ?0.6 C | Bath Stability: ?0.05 C | Stabilization Time: 20 Min. | Heating Time: 30 to 32 Min. (Ambient to 650 C) | Resolution: 0.1 C | Units: C / F Switchable | Display: Graphical with LED Backlight | Power Supply: 230V AC 5% / 50Hz,1.2 KW for 650DBC
- Transmitter Supply: 24V DC 10% (Loop Powered) |Block Diameter: 25.4 mm | Block Depth: 120 mm | Insertion Tube Depth: 110 mm | Temperature Setting: Digital Display through feather touch keypad | Display Stability: ?0.2 C | Radial uniformity Fixed Steps for: ?0.3 C with similar probes | Switch Test: Continuity check with OPEN / CLOSE indication |
- Measuring Parameters: mA, mV, Volts, Ohms, RTD3 (Pt 100)3 | mA Range: 0 to 25 mA; Resolution: 0.001 mA; Accuracy: ?0.025% of Reading + 10 ?A | mV Range: 0 to 1000.0 mV; Resolution: 0.01 mV; Accuracy: ?0.025% of Reading + 0.25 mV | Volts Range: 0 to 10.000 V; Resolution: 0.001 V; Accuracy: ?0.025% of Reading + 3 mV | Ohms Range: 0 to 400 Ohms; Resolution: 0.01 Ohms; Accuracy: ?0.025% of Reading + 0.1 Ohm | RTD3 Range: -200 to 8500 C; Resolution: 0.10 C; Accuracy: ?0.025% of Reading + 0.30 C |
- Thermocouple Types: T, J, K, N, R, S | Thermocouple Range( T,J,K,R,S): -200 to 400 C; Resolution: 0.1 C; Accuracy: ?0.025 % of Reading + 1 C |Thermocouple Range(R,S): 300 to 1760 C; Resolution: 1 C; Accuracy: ?0.025 % of Reading + 1 C |
- Supply Scope: 1 Unit of DBC-02 Dry Block Calibrator, Power Cable, 1 Unit of Test Lead (2 Wire), Insertion Tube: Dual Hole - 1 x 1/4" + 1 x 12.5 mm, Dual Hole - 1 x 1/4" + 1 x 8.2 mm, 1 Unit of Insertion Tool, 2no.s of 6A Spare Fuses, Instruction Manual and Factory Calibration Certificate | Applications: Calibration Labs, Pharmaceutical Divisions, Thermal Plants, Metallurgical Plants Temp dry well block temperature probe calibrator rtd k type thermocouple stimulator calibration equipment.
8 Channel Datalogger with Standard Software for Pharmaceutical Industries, Freezers, Digital data logger , temperature recorder, Cold Chains, Autoclaves, Chemical Industry Alongwith Factory Calibration Certificate Model: AI-800S - Product Features
- The instrument can at a time measure 8 inputs on its 8 channels. These inputs can be all 8 of one type (say all 8 of vacuum or Pressure or Temperature etc.) Or of different types; 2) Alternatively, the instrument can be used to read & record any 1 Input, on any 1 Channel & the remaining channels can be disabled using the Front keys.
- Scanner: The instrument can be used as a plane scanner where in the only purpose of the instrument is to display the input value from the sensors. Scanner with Memory (Data Logger): The instrument can be Provided with 5000 Readings Memory Built In for each of the 8 Channels & provided with any standard communication port (RS 232 or RS485) for Computer connectivity
- Scanner With Printer Port: The instrument can be provided with a Parallel printer port for printing directly onto a 80/132 Channel Printer Without using a computer. The print interval (time gap between Successive Printouts) can be programmed using the front keys; Input Type: 8 Nos. of Vacuum / Pressure / Humidity (4-20 mA), Temperature (4-20 mA) RTD Pt-100 Sensors, 0 -1/ 0-5 / 0-10 V DC, Any Standard Thermocouple (To be specified at time of ordering); Accuracy: ?0.25% of Full Scale.
- Display: 1 Digit for Channel No; 4 Digits for Process Variable; Memory: 5000 Records of Each of the 8 Channels; Modes: Channel Skip, Hold & Auto Modes. Scan Time: 1 to 59 seconds (User Programmable); Relay/ Alarm: 2 Relay Contacts for Alarm & Trip; Power Supply: 230V AC, 50Hz, Single Phase.
- Software: ACE SOFT 21 CFR Part 11 Compliant Software With Audit Trail Reporting, Online Tabular View & Data Graphing| Supply Scope: 1 Unit of 8 Channel Datalogger, Instruction Manual and Factory Calibration Certificate | Applications: Applications: Pharmaceutical Industries, Freezers, Cold Chains, Autoclaves, Chemical Industries. Multichannel temperature humidity universal recorder cryogenic data logger laboratories
Dry Block Temperature Calibrator (Range: 50?C to 350?C) with Thermocouples (T, J, K, N, R, S) for Calibration Labs, Pharmaceutical Divisions, Thermal Plants, Metallurgical Plants Model: AI-DBC-01 - Product Features
- Range: Ambient to 350 C | Accuracy: ?0.4 C | Bath Stability: ?0.05 C | Stabilisation Time: 15 Min. | Heating Time: 18 to 20 Min. (Ambient to 350 C) | Cooling Time: 30 to 35 Min (350 to 100 C) | Resolution: 0.1 C | Units: C / F Switchable | Display: Graphical with LED Backlight | Power Supply: 230V AC 5% / 50Hz,1.2 KW for 500 W for 350 DBC |
- Transmitter Supply: 24V DC 10% (Loop Powered) |Block Diameter: 25.4 mm | Block Depth: 120 mm | Insertion Tube Depth: 110 mm | Temperature Setting: Digital Display through feather touch keypad | Display Stability: ?0.2 C | Radial uniformity Fixed Steps for: ?0.3 C with similar probes | Switch Test: Continuity check with OPEN / CLOSE indication |
- Measuring Parameters: mA, mV, Volts, Ohms, RTD3 (Pt 100)3 | mA Range: 0 to 25 mA; Resolution: 0.001 mA; Accuracy: ?0.025% of Reading + 10 ?A | mV Range: 0 to 1000.0 mV; Resolution: 0.01 mV; Accuracy: ?0.025% of Reading + 0.25 mV | Volts Range: 0 to 10.000 V; Resolution: 0.001 V; Accuracy: ?0.025% of Reading + 3 mV | Ohms Range: 0 to 400 Ohms; Resolution: 0.01 Ohms; Accuracy: ?0.025% of Reading + 0.1 Ohm | RTD3 Range: -200 to 8500 C; Resolution: 0.10 C; Accuracy: ?0.025% of Reading + 0.30 C |
- Thermocouple Types: T, J, K, N, R, S | Thermocouple Range(T,J,K,N): -200 to 400 C; Resolution: 0.1 C; Accuracy: ?0.025 % of Reading + 1 C | Thermocouple Range(R, S): 300 to 1760 C; Resolution: 1 C; Accuracy: ?0.025 % of Reading + 1 C |
- Supply Scope: 1 Unit of DBC-01 Dry Block Calibrator, Power Cable, 1 Unit of Test Lead (2 Wire), Insertion Tube: Dual Hole - 1 x 1/4" + 1 x 12.5 mm, Dual Hole - 1 x 1/4" + 1 x 8.2 mm, 1 Unit of Insertion Tool, 2no.s of 6A Spare Fuses, Instruction Manual and Factory Calibration Certificate | Applications: Calibration Labs, Pharmaceutical Divisions, Thermal Plants, Metallurgical Plants.
Testo 545 Light Intensity Measuring Instrument With Data Storage - Product Features
- Light Range: 0 to 100000 Lux, Accuracy: Accuracy to DIN 13032-1: F1 = 6 % V (Lambda) adaptation, F2 = 5 % cos like rating, Class C according to DIN 5032-7, Resolution: 1 Lux for (0 to 32000 Lux), 10 Lux for (0 to 100000 Lux)
- Operating Temperature: 0 C to +50 C; Storage Temperature: -20 C to +70 C; Display type: LCD; Display size: 2 lines
- Data transfer: RS232 cable connects instrument to PC (1.8 m) for data transfer; Memory: 3,000 measuring values
- Housing: ABS; Battery type: 9V block battery; Battery life: 50 h; Connection: Fixed cable, coiled
- Accessories: Testo 545 light meter with permanently attached sensor, calibration certificate, batteries.
Industrial Process Calibrator used for Calibration of process control instruments, Temperature & pressure transmitters, I/P convertors, Field-level transmitters, Flow transmitters Model: BTH C9 - Product Features
- Measuring Parameters: Frequency, OHM, Analog Transducer, DC mA, RTD, Thermocouples, Resistance, RTD Measurement, TC Measurrement, Frequency Count, Diode Test & Continuity Test.
- Process Meter Measurements: Range: DC Voltage Measurement: Range: 4.000V, Resolution: 0.001V, Accuracy: 0.2% + 4; Range: 40.00V, Resolution: 0.01V, Accuracy: 0.2% + 4; Range: 400.0V, Resolution: 0.1V, Accuracy: 0.2% + 4; DC mV Measurement: Range: 40.00mV, Resolution: 0.01mV, Accuracy: 0.5% + 6; Range: 400.0mV, Resolution: 0.1mV, Accuracy: 0.2% + 4
- AC Voltage Measurement: Range: 400.0mV, Resolution: 0.1mV, Accuracy: 1.0% + 4; Range: 4.000V, Resolution: 0.001V, Accuracy: 0.5% + 4; Range: 40.00V, Resolution: 0.01V, Accuracy: 0.5% + 4; Range: 400.0V, Resolution: 0.1V, Accuracy: 0.5% + 4; DC Current Measurement: Range: 40.00mA, Resolution: 0.01mA, Accuracy: 0.2% + 4; Range: 400.0mA, Resolution: 0.1mA, Accuracy: 0.2% + 4
- AC Current Measurement: Range: 40.00mA, Resolution: 0.01mA, Accuracy: 0.5% + 4; Range: 400.0mA, Resolution: 0.1mA, Accuracy: 0.5% + 4; Operating Temperature: 5 C to 50 C; Operating Relative Humidity: <80% RH, Storage Temperature: -10 C to 55 C, Storage Humidity: < 90% RH
- Power Supply: 6V batteries (4*1.5V alkaline AAA batteries or 4*1.5V Ni-MH AAA batteries); Maximum Voltage: 600Vp-p (Maximum Voltage between all input jacks & earth ground), 30V DC (Maximum Voltage between all output jacks & earth ground); Accessories: A copy of user manual, a set of industrial test lead (with alligator) clips and two 63mA/250V fast-blow fuses; Safety: Compiled with IEC61010 (Safety standard issued by International Electro-technical commission.
Testo 270 Oil Analysis Kit Oil Thermometer for Temperature and Total Polar Material Measurement in Deep Fryers Digital Thermometer for Cooking Oil in Fryers - Product Features
- TEMPERATURE AND TPM; The testo 270 temperature gun checks temperature and Total Polar Material, thus ensuring that only high quality, nutritionally adequate foods, are served to customers
- QUICK AND COST-EFFECITVE; The temperature gauge works fast and reliably while enabling significant cost saving by decreasing the probability of changing the expensive resource oil too soon
- CONVENIENT; The kitchen appliance for deep fryer with oil filtration is designed in a way that protects the hand from hot oil. It is cleanable under running water (IP65) and has an intuitive traffic-light system for TPM levels
- QUALITY ASSURANCE; Determining the TPM in a deep fryer with basket is a key method to ensure high quality frying oil and hence fried food with a harmless nutritional value. It should never exceed 24%
- USER-FRIENDLY; Its ergonomic, rugged design, backlit display, color-coded alarms, and hold- and auto-hold function make the temperature probe a practical, intuitive everyday tool
High Accuracy Oxygen Gas Detector (Range: 0-25 Vol%) Drager Personal Safety for Zone 0 with IP68 Protection for Chemical Industries by Drager Model: PAC-6500 - Product Features
- Part Number: 83 26 332 | Features: Easy fastening with tightly closing crocodile clip | Illuminating D-Light shows device is tested and ready | Robust housing with handy design for tough conditions | Clear colour coding prevents mistakes
- Easily replaceable Filter membrane protects the sensor | Large display shows all important information | 360 alarm signal can be easily seen from all sides
- Drager Pac 6500 O2: Measuring Range: 0 - 25 Vol.% | Alarm thresholds A1/A2: 19 / 23 Vol.% | Operating Temperature: -30 C to +55 C | Operating Humidity: 10 to 90% RH (non condensing) | Operating Pressure: 700 - 1,300 hPa
- Battery Life: 2 Years | Approval: cCSAus, IECEx, ATEX, CE | Dimensions: 64 X 84 X 20 mm | Weight: 106 Grams |
- Supply Scope: 1 unit of Drager Pac 6500-O2 monitor, 1 unit of Calibration Cap, Instuction Manual, Software CD | Applications: Chemical Industry, Oil & Gas industry, Mining, Federal Government, Ignition Interlock Services
Ace AI-DPI-2200 Hand Operated Vacuum and Pressure Pump Range: -1 to 3 bar (Vacuum Gauge Alongwith Pump) - Product Features
- Model: AI-DP1-2200; Measuring Parameters: Pressure and Vacuum | Vacuum Range: Ambient to -0.9 Kg/Cm?; Pressure Range: Ambient to 30 Kg/Cm (30 Bar)
- Model: AI-DP1-2200; Measuring Parameters: Pressure and Vacuum | Vacuum Range: Ambient to -0.9 Kg/Cm?; Pressure Range: Ambient to 30 Kg/Cm (30 Bar)
- Material Of Construction: Aluminium and Stainless Steel; Weight Approx. 1.5 Kgs.
- Supply Scope: Vacuum gauge with Hand pump and Instruction manual
- Applications: Calibration Labs, Field Calibration, Pressure Gauge Calibration, Pressure Transmitter Calibration.hand pump portable vaccum guage hand operated pneumatic low pneumatic pressure comparator calibrator 30 bar